The UNI-XU® UXC101 Control Card has been developed to perfectly compliment the motor rollers and has a comprehensive list of features to optimise your conveyor control.
Power Voltage | 24VDC +/- 10%. | |
---|---|---|
Static Current | 70mA | |
Starting Current | 4A | |
Operational Functions | a. With 20mA driving force, 4 sets of NPN or PNP output signals are able to drive external Relay, PLC or Remote 1/0 etc. | |
b. Motor speed controlled by either using the on board DIP switches for 16 increment speed selection, or by using external DC 0 – 10V voltage. | ||
c. Variable acceleration/deceleration settings (0.2 – 0.6 seconds). | ||
d. The ability to work with PNP or NPN devices using DIP switches to select. | ||
LED Indication | Displays a solid green light when power on and flashes for 7 kinds of fault notifications. | |
Power Protection | a. Built-in fuse. | |
b. Built-in reverse polarity protection to prevent damage due to wiring errors. | ||
Thermal Protection | a. If the control card gets above 75°C, the motor will shut down and will restart automatically when it cools down to 70°C. | |
b. Motor will shut down when the temperature is above 100°C; below 95°C will operate at half speed; below 90°C will operate at full speed. | ||
Braking System (on Un-Braked Motor Rollers) | Uses the reverse torque produced by the back EMF to brake. | |
Mechanical Braking (on Braked Motor Rollers) | Braking Start | Spring applied electromagnetic brake applied 200mS after stop signal is applied. |
Effect on Current Draw | An additional 250mA for the first 100mS after the motor roller is started. This then decreases to 125mA. | |
Environmental Conditions | Temperature | 0°C – 40°C (32°F – 104°F). |
Humidity | <90% RH (non-condensing). | |
Vibration | <0.5 G |